이 문서는 분류가 되어 있지 않습니다. 분류:분류에서 적절한 분류를 찾아 문서를 분류해주세요!
1. 개요 [편집]
HP 서버 전용 점검 명령어를 정리한 문서이다.
2. Gen6~8 이하 명령어 [편집]
디스크 점검
hpacucli ctrl all show config
캐시배터리 점검
hpacucli ctrl all show status
3. Gen9 서버 명령어 [편집]
디스크 점검
hpssacli ctrl all show config
디스크 점검
hpssacli ctrl all show status
4. Gen10 서버 명령어 [편집]
디스크 점검
ssacli ctrl all show config
캐시배터리 점검
ssacli ctrl all show status
4.1. 정상 출력 [편집]
# xxx ctrl all show config
HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded) (sn: PWXKV0CRHXXXXX)
Internal Drive Cage at Port 1I, Box 3, OK
Internal Drive Cage at Port 2I, Box 3, OK
Port Name: 1I (Mixed)
Port Name: 2I (Mixed)
Array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (279.37 GB, RAID 1, OK)
physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SAS HDD, 300 GB, OK)
physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SAS HDD, 300 GB, OK)
Array B (SAS, Unused Space: 1 MB)
logicaldrive 2 (1.09 TB, RAID 5, OK)
physicaldrive 1I:3:3 (port 1I:box 3:bay 3, SAS HDD, 600 GB, OK)
physicaldrive 1I:3:4 (port 1I:box 3:bay 4, SAS HDD, 600 GB, OK)
physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SAS HDD, 600 GB, OK)
physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SAS HDD, 600 GB, OK, auto replace spare)
# xxx ctrl all show status
Smart Array P420 in Slot 1 Controller Status: OK
Cache Module Status: OK
Battery/Capacitor Status: OK
# xxx ctrl all show status
Smart Array P420 in Slot 1 Controller Status: OK
Cache Module Status: OK
Battery/Capacitor Status: Recharging[1]
4.2. 비정상 출력 [편집]
HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded) (sn: PWXKV0CRHXXXXX)
Internal Drive Cage at Port 1I, Box 3, OK
Internal Drive Cage at Port 2I, Box 3, OK
Port Name: 1I (Mixed)
Port Name: 2I (Mixed)
Array A (SAS, Unused Space: 0 MB)
logicaldrive 1 (279.37 GB, RAID 1, OK)
physicaldrive 1I:3:1 (port 1I:box 3:bay 1, SAS HDD, 300 GB, Predictive Failure[2])
physicaldrive 1I:3:2 (port 1I:box 3:bay 2, SAS HDD, 300 GB, OK)
Array B (SAS, Unused Space: 1 MB)
logicaldrive 2 (1.09 TB, RAID 5, OK)
physicaldrive 1I:3:3 (port 1I:box 3:bay 3, SAS HDD, 600 GB, Failed[3])
physicaldrive 1I:3:4 (port 1I:box 3:bay 4, SAS HDD, 600 GB, OK)
physicaldrive 2I:3:5 (port 2I:box 3:bay 5, SAS HDD, 600 GB, OK)
physicaldrive 2I:3:6 (port 2I:box 3:bay 6, SAS HDD, 600 GB, OK, active spaer for 1I:3:3[4])
# xxx ctrl all show status
Smart Array P420 in Slot 1 Controller Status: OK
Cache Module Status: Degraded[5]
Battery/Capacitor Status: Fail
# xxx ctrl all show status
Smart Array P420 in Slot 1 Controller Status: OK
Cache Module Status: Fail[6]
Battery/Capacitor Status: OK (or Unkown)